Why water splashes: New theory reveals secrets

New research from the University of Warwick generates fresh insight into how a raindrop or spilt coffee splashes.

Dr James Sprittles from the Mathematics Institute has created a new theory to explain exactly what happens - in the tiny space between a drop of water and a surface - to cause a splash.

Water splash

When a drop of water falls, it is prevented from spreading smoothly across a surface by a microscopically thin layer of air that it can't push aside - so instead of wetting the surface, parts of the liquid fly off, and a splash is generated.

A layer of air 1 micron in size - fifty times smaller than the width of a human hair - can obstruct a 1mm drop of water which is one thousand times larger.

This is comparable to a 1cm layer of air stopping a tsunami wave spreading across a beach.

Dr Sprittles has established exactly what happens to this miniscule layer of air during the super-fast action by developing a new theory, capturing its microscopic dynamics - factoring in different physical conditions, such as liquid viscosity and air pressure, to predict whether splashes will occur or not.

The lower the air pressure, the easier the air can escape from the squashed layer - giving less resistance to the water drop - enabling the suppression of splashes. This is why drops are less likely to splash at the top of mountains, where the air pressure is reduced.

Understanding the conditions that cause splashing enables researchers to find out how to prevent it - leading to potential breakthroughs in various fields.

In 3D printing, liquid drops can form the building blocks of tailor-made products such as hearing aids; stopping splashing is key to making products of the desired quality.

Splashes are also a crucial part of forensic science - whether blood drops have splashed or not provides insight into where they came from, which can be vital information in a criminal investigation.

Dr Sprittles comments:

"You would never expect a seemingly simple everyday event to exhibit such complexity. The air layer's width is so small that it is similar to the distance air molecules travel between collisions, so that traditional models are inaccurate and a microscopic theory is required.

"Most promisingly, the new theory should have applications to a wide range of related phenomena, such as in climate science - to understand how water drops collide during the formation of clouds or to estimate the quantity of gas being dragged into our oceans by rainfall."

The research, 'Kinetic Effects in Dynamic Wetting', is published in Physical Review Letters.

For more information, visit:-







Wednesday, 29 July 2015

On this day in Science History: The First Iron Lung was Installed

In 1927, the first iron lung (electric respirator) was installed at Bellevue hospital in New York for the post war polio epidemic. The first iron lung was developed at Harvard University by Phillip Drinker and Louis Agassiz Shaw built with two vacuum cleaners.

The iron lung is a negative pressure machine which surrounds the patient's body except for the head, and alternates a negative atmospheric pressure with the ambient one, resulting in rhythmic expansion of the chest cage (and thus inhalation) in response to the negative extra thoracic pressure. During periods of ambient extrathoracic pressure, the lungs deflate.

Humans, like most animals, breathe by negative pressure breathing: the rib cage expands and the diaphragm contracts, expanding the chest cavity. This causes the pressure in the chest cavity to decrease, and the lungs expand to fill the space. This, in turn, causes the pressure of the air inside the lungs to decrease (it becomes negative, relative to the atmosphere), and air flows into the lungs from the atmosphere: inhalation. When the diaphragm relaxes, the reverse happens and the person exhales. If a person loses part or all of the ability to control the muscles involved, breathing becomes difficult or impossible.

The person using the iron lung is placed into the central chamber, a cylindrical steel drum. A door allowing the head and neck to remain free is then closed, forming a sealed, air-tight compartment enclosing the rest of the person's body. Pumps that control airflow periodically decrease and increase the air pressure within the chamber, and particularly, on the chest. When the pressure is below that within the lungs, the lungs expand and atmospheric pressure pushes air from outside the chamber in via the person's nose and airways to keep the lungs filled; when the pressure goes above that within the lungs, the reverse occurs, and air is expelled. In this manner, the iron lung mimics the physiological action of breathing: by periodically altering intrathoracic pressure, it causes air to flow in and out of the lungs. The iron lung is a form of non-invasive therapy.